Sign In | Join Free | My udpf.com |
|
Brand Name : Kingpo
Place of Origin : China
MOQ : 1
Price : To be quoted
Payment Terms : T/T
Technical Specifications for High-Voltage, High-Current Test System
Input AC Power | AC380V±10%/50Hz | |
DC Side Voltage | Accuracy | ±0.05% of FS |
Stability | ±0.05% of FS | |
DC Side Current | Accuracy | ±0.05% of FS |
Stability | ±0.1% of FS | |
Efficiency | Maximum Charge and Discharge Efficiency | >94% |
Time | Current Response Time | Maximum current rise time 10ms (+10%-+90%) |
Current Switching Time | Forward and reverse current time 20ms (-90%-+90%) | |
Data Recording | Data Recording Conditions | Minimum time interval: 10ms |
Minimum voltage interval: 1.6V | ||
Minimum current interval: 0.6A | ||
Recording Frequency | ≤50Hz | |
Charge | Charging Mode | Constant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging, battery pack constant current Constant voltage charging |
Cut-off Conditions | Main channel: voltage, current, relative time, capacity, -△V | |
Discharge | Discharge mode | Constant current discharge, constant power discharge, constant resistance discharge |
Cut-off Conditions | Main channel: voltage, current, relative time, capacity, -△V | |
Working Condition Simulation | Charging Mode | Current, power |
Discharge Mode | Current, power | |
Cut-off Conditions | Time, line number | |
Continuous Switching of Charge and Discharge | One simulation step can realize continuous switching from charging to discharging | |
Limitation of the Number of Lines in the Work Step File | 1 million | |
Cycle | Cycle Measurement Range | 1~65535 times |
Number of Steps in a Single Cycle | 254 | |
Nested Loops | With nested loop function, supporting up to 3 layers of nesting | |
Protect | Safety protection conditions can be set, and the setting parameters include: voltage upper limit, voltage lower limit, Current upper limit, current lower limit, capacity upper limit, delay time. Built-in device temperature protection. | |
Channel Characteristics | The constant current source and constant voltage source adopt a double closed loop structure | |
Number of Channels Per Unit | 1/2/3/4 | |
Energy Feedback | The discharged energy can be fed back to the grid | |
Channel Control Mode | Independent control | |
Noise | ≤75dB | |
Database | Use MySQL database to manage test data | |
Host Computer Communication Method | Based on TCP/IP protocol | |
Data Output Method | EXCEL 3003,2010,TXT | |
Communication Interface | Network port/reserved CAN interface. | |
Support DBC File Export | Support |
![]() |
1000V-1500V High-Voltage Battery Test System with 94% Efficiency Images |